地址:江苏省扬州市广陵区头桥镇弘扬西路(红桥新纪园加油站西侧)
电话:0514-87264723 87268723
传真:0514-87268726
SMA-KE-Y
Brass SMA Specifications
Electrical |
||
Impedance |
50 Ω |
|
Frequency Range |
.141" & .085" semi-rigid cable: 0-18 GHz |
|
Voltage Rating |
RG-58, 141, 142: 500 volts peak |
|
Dielectric Withstanding Voltage |
.141" & RG-58 Cables: 1,000 VRMS |
|
VSWR |
Straight connector, .141": 1.05 + .005 f (GHz) |
|
Contact Resistance |
Center contact: 2.0 mΩ |
|
Insulation Resistance |
5,000 MΩ |
|
Insertion Loss |
dB maximum = .06v[f(GHz)] |
|
RF Leakage |
-90 dB minimum @ 2.3 GHz |
|
Mechanical |
||
Mating |
.250-36 threaded coupling |
|
Mating Torque |
Minimum: 2 inch pounds (12 N.cm) |
|
Connector Durability |
100 matings |
|
Material |
||
Bodies, Coupling Nuts, Other Metal Parts (except as noted) |
Brass per QQ-B-626 |
|
Contacts |
Male: Brass |
|
Center Contact Plating |
.000030" minimum gold |
|
Plating (Other Metal Parts) |
Standard .000010" gold or nickel plated |
|
Insulator |
TFE fluorocarbon |
|
Gaskets |
Silicone rubber |
|
Crimp Ferrule |
Seamless copper tubing alloy |
|
Environmental |
||
Temperature Range |
- 65°C to +165°C |
|
Thermal Shock |
MIL-STD-202 method 107 (test condition B) except high temperatures @ + 200°C |
|
Vibration |
MIL-STD-202 method 204 (test condition D) |
|
Shock |
MIL-STD-202 method 213 (test condition I). No discontinuity permitted. |
|
Corrosion |
MIL-STD-202 method 101 (test condition B) 5% salt solution |
|
Moisture Resistance |
MIL-STD-202 method 106, except step 7b (vibration) omitted, and high humidity measurements do not apply |
|
Weatherproofing |
Crimp type: heat shrink tubing |
|
Altitude |
MIL-STD-202 method 105 (test condition C), no corona at 70,000 feet. |
|
Military Specifications |
||
MIL-C-39012 & MIL-C-83517 SMA Specification Sheets |
As applicable |
Note: These characteristics are typical but may not apply to all connectors.